ControlZ EnvisaLink DSC plugin icon
ControlZ EnvisaLink DSC HomeSeer HS4 plugin

Your DSC PowerSeries alarm, inside HomeSeer

ControlZ EnvisaLink DSC connects a DSC PowerSeries alarm panel to a HomeSeer HS4 hub through an EyezOn EnvisaLink 3 or 4. Zones become HomeSeer sensors with a Bypass control, partitions can be armed Away or Stay and disarmed, and panel troubles, command outputs and keypad functions are ready for HomeSeer Events. It talks to the EnvisaLink on your home network only.

For DSC PowerSeries panels only. Honeywell Vista, EyezOn UNO and DSC Neo each have their own plugin — see Which EnvisaLink plugin?

Version 1.0.0.33 · Submitted to the HomeSeer Plugin Store · HomeSeer HS4 4.2 or later on Windows or Linux

Store status

ControlZ EnvisaLink DSC has been submitted to the HomeSeer Plugin Store and is waiting for HomeSeer's review. It isn't available to download from this site. If you have a DSC PowerSeries panel and would like to help test it, ask about the beta.

  • Submitted: version 1.0.0.29 is with HomeSeer for review, and store build 1.0.0.33 is staged to replace it.
  • Price: US$9.95 after HomeSeer's 30-day free trial, licensed through the HomeSeer Plugin Store.
  • Verified: TPI login, keepalive and reconnect; zone open / closed and bypass status; partition status with Arm Away, Arm Stay and Disarm; Sync and Repair; migration from the stock EnvisaLink plugin.
  • Please test: the Keypad page and keypad lights, panel troubles, PGM outputs 1–4, the TPI proxy with Home Assistant, EnvisaLink 3, and HomeSeer on Windows.
  • Upgrading from a build before 1.0.0.30: HomeSeer drops the old “ControlZ EnvisaLink” entry. Re-enable the plugin once in Plugins → Manage → ControlZ EnvisaLink DSC and your devices reattach.

Choose the right one

Which EnvisaLink plugin?

There are four ControlZ EnvisaLink plugins. Each speaks a different EnvisaLink TPI dialect, so pick the one that matches your panel and the firmware or mode your EnvisaLink runs.

EnvisaLink DSC

DSC PowerSeries with an EnvisaLink 3 or 4 on DSC firmware. Zones with bypass, Away / Stay, panel troubles, PGMs, a graphical keypad and an optional proxy. Submitted to the HomeSeer Plugin Store. You are on this page.

EnvisaLink Ademco

Honeywell / Ademco Vista with an EnvisaLink 3 or 4 on Honeywell firmware. Zones, Away / Stay / Night, the two-line ALPHA keypad display and function keys A–D. Ready to submit. EnvisaLink Ademco

EnvisaLink UNO

EyezOn UNO standalone: UNO Hybrid, SOLO, or a DUO / EVL4 MAX in standalone mode. Up to 128 zones, Away / Stay, bypass and panics. Ready to submit. EnvisaLink UNO

EnvisaLink Neo

DSC Neo through an EVL4 MAX or DUO activated in Universal mode. Arm, disarm and coarse armed / ready / alarm status only, with no zone devices. In development. EnvisaLink Neo

Run only one of them at a time: the EnvisaLink accepts a single TPI client on port 4025. A DSC PowerSeries panel needs this plugin; a DSC Neo panel does not speak the PowerSeries TPI and needs EnvisaLink Neo instead.

How it works

One local connection, live panel status

The plugin owns the EnvisaLink's single TPI session and turns what the panel reports into HomeSeer devices.

  1. Connect to the EnvisaLink

    The plugin opens one TCP connection from your HomeSeer hub to the EnvisaLink TPI on port 4025, logs in with the TPI password, and asks once for a status report and zone timers.

  2. Follow the panel live

    Zone, partition and trouble changes arrive as the panel reports them. A keepalive every 60 seconds (minimum 15) holds the session, and the plugin reconnects five seconds after any drop.

  3. Use native HomeSeer devices

    Zones, partitions, the panel, PGM outputs and a keypad device appear as HomeSeer devices for Events, dashboards and apps.

  4. Control from HomeSeer

    Arming, disarming, bypass, keystrings, panics and outputs are sent as documented DSC TPI commands. Your panel, sirens and any monitoring contract keep working as before.

Features

What you get in HomeSeer

Zones, partitions, panel status, outputs and keypad functions as HomeSeer devices and plugin pages.

🚪

Zone sensors

Each zone (1–64) is a HomeSeer sensor showing Open, Closed or Alarm. Set its type — door, window, motion, smoke, CO, water or glass break — and its partition (1–8).

⏭️

Bypass per zone

A Bypass feature under each zone shows Bypassed or Active and toggles bypass from HomeSeer. There's no separate “Bypassed” sibling device to manage.

🔐

Arm Away and Arm Stay

Arm each partition from HomeSeer, the Partitions page or an Event. The DSC TPI arms without a code, just like quick-arm on a keypad.

🔓

Disarm

Disarm uses the user code stored in Settings. Leave the code empty and HomeSeer can arm but never disarm. The Partitions page asks before disarming.

📊

Partition status

Ready, Not Ready, Armed Away or Stay, Exit and Entry delay, Alarm and Disarmed, updated as the panel reports them.

🛠️

Panel troubles

A DSC Panel device reports battery, AC power, bell and FTC troubles plus a summary, ready to use in HomeSeer Events.

⌨️

Graphical keypad

Send keystrings of up to six keys or single keys, with shortcuts for chime, the bypass menu and installer entry. See live partition state, open and bypassed zone counts, and the eight keypad lights for partition 1.

🚨

Panic keys

Fire, Ambulance and Police panics, each behind a confirmation on the Keypad page. On a monitored system a panic triggers a real emergency response.

⚡

PGM outputs

Name and activate command outputs 1–4 from the Outputs page or from HomeSeer Events. The Outputs page asks before activating.

🎛️

DSC Keypad device

Panic Fire, Ambulance and Police, Door Chime and Bypass Menu as HomeSeer features you can trigger from Events. Door Chime and Bypass Menu act on partition 1.

🧩

Tidy HomeSeer categories

Zones are filed under Sensors, Security and ControlZ. Partitions go under Security and ControlZ only, so arm controls don't crowd your sensor lists.

🔁

Optional TPI proxy

The EnvisaLink accepts one client. Turn on the proxy (off by default, port 4026) and Home Assistant can share the plugin's session instead of competing for it.

📥

Move from the stock plugin

Import zone names and types from the stock HomeSeer EnvisaLink plugin's devices, or paste its INI or JSON text, instead of typing every zone again.

🩹

Self-healing devices

Sync and Repair rebuild HomeSeer devices from the plugin's saved zone list, even while the EnvisaLink is offline, and merge duplicate partition devices.

📱

ControlZ app

With the free ControlZ Export plugin, zones and partitions can appear in the ControlZ app for iPhone, iPad and Mac through your own hub.

Compatibility

Supported panels and EnvisaLink models

ControlZ EnvisaLink DSC speaks the classic DSC TPI. Other panel families need a different ControlZ plugin.

Supported DSC TPI

  • Panels — DSC PowerSeries.
  • Modules — EyezOn EnvisaLink 3 and EnvisaLink 4 running DSC firmware. Choose the EVL version in Settings; EnvisaLink 3 passwords are limited to 6 characters.
  • Size — partitions 1–8, zones 1–64 and command outputs (PGM) 1–4.
  • Keypad lights — reported by the panel for partition 1 only.

Not supported Use a sibling

  • Honeywell / Ademco Vista — use EnvisaLink Ademco.
  • EyezOn UNO standalone — use EnvisaLink UNO.
  • DSC Neo in Universal mode — use EnvisaLink Neo.
  • Remote or cloud access — no EyezOn cloud or Connect2Go path. Local TPI only.

HomeSeer hub HS4 4.2+

  • Windows or Linux — one package covers both.
  • Same network — the hub must reach the EnvisaLink on your LAN.
  • Plugin pages — Status, Zones, Partitions, Keypad, Outputs, Settings and Help.
  • Footprint — files stay inside the HomeSeer folder.

Beta reports that include your panel model, EnvisaLink version and firmware are the most useful part of testing.

Requirements

What you need

Check these before you connect.

  1. A HomeSeer HS4 hub

    HS4 4.2.0.0 or later on Windows or Linux, on the same network as the EnvisaLink.

  2. An EnvisaLink and a DSC panel

    An EyezOn EnvisaLink 3 or 4 with DSC firmware, wired to a DSC PowerSeries panel with the zones and partitions you care about programmed.

  3. The TPI password

    The factory default is user. Change it if the hub is on another subnet: the EnvisaLink 4 firewalls cross-subnet logins that use the default.

  4. No other TPI client

    Disable the stock HomeSeer EnvisaLink plugin and stop Home Assistant or any other tool connecting to port 4025 — or point them at the plugin's proxy.

  5. Optional: a user code

    Only if HomeSeer should be able to disarm. Without it, HomeSeer can arm but not disarm.

Security & licensing

Local, careful, and not a monitoring service

What the plugin stores, what it sends, and what it costs.

🏠

Not a monitored alarm service

The plugin adds HomeSeer as another keypad. Your panel, its sirens and any monitoring contract work as before, and nothing here replaces professional monitoring.

🌐

Local only

One outbound TCP connection from the hub to your EnvisaLink. No EyezOn cloud, no ControlZ server and no telemetry.

🔑

Codes stay on your hub

The TPI password and optional user code are entered in password fields, saved in the plugin's registry file inside the HomeSeer folder, sent only to your EnvisaLink, and never written to any log. The file is plain JSON, so protect access to the hub.

📡

The TPI is unencrypted

Keep the EnvisaLink on a trusted network segment. The proxy password also travels in plain text: leave the proxy off unless you need it, change its password first, and bind it to a specific address.

⚠️

HomeSeer controls act immediately

Arming needs no code on DSC, so any HomeSeer user or Event that can press the control can arm. Admin pages confirm disarm, panic and PGM; device controls and Events don't. HomeSeer's own login is the only permission check.

🧾

Logs and screenshots

Logs include the EnvisaLink's address and the Status page shows the last raw TPI line — never the password or user code. They can show your LAN address and zone names, so check them before sharing.

💳

Licence and price

US$9.95 after HomeSeer's 30-day free trial, bought and licensed through the HomeSeer Plugin Store. Beta keys are only used in ControlZ test builds for beta testers.

Store artwork

How it looks in the Plugin Store

Screenshots of the plugin's pages will be added once captures with masked addresses are ready.

This is the listing image prepared for the HomeSeer Plugin Store. The keypad artwork is a generic illustration by ControlZ, not an EyezOn or DSC product.

ControlZ EnvisaLink DSC store artwork: a dark alarm keypad with a blue display above a Plugin for HS4 banner

Plugin Store listing image

The dark keypad marks the DSC plugin. The Ademco, UNO and Neo plugins each have their own artwork.

HomeSeer Plugin Store · listing artwork

Setup

From install to live zones

The plugin's Help page and User Manual cover every page and setting.

  1. Install and enable

    Install from the HomeSeer Plugin Store once it's listed (beta testers receive a test package), then enable it in Plugins → Manage.

  2. Free the TPI port

    Disable the stock HomeSeer EnvisaLink plugin and anything else connected to port 4025.

  3. Connect

    In Plugins → ControlZ EnvisaLink DSC → Settings, enter the EnvisaLink host, TPI password and EVL version, plus a user code if HomeSeer should disarm. Choose Save & reconnect.

  4. Set up zones

    Open Zones and choose Seed zones (or import from the stock plugin). Name each zone, set its type and partition, then choose Sync HS devices.

  5. Add the extras you want

    Use Keypad for keystrings and panics, Outputs for PGMs, turn on the TPI proxy for Home Assistant, and refresh ControlZ Export if you use the ControlZ app.

Interested in ControlZ EnvisaLink DSC?

It's waiting for HomeSeer's review. Use the contact form and choose ControlZ to ask about the beta, to be told when it's listed, or to ask a question.

EnvisaLink and EyezOn are trademarks of EyezOn; DSC and PowerSeries are trademarks of their owner. They are used only to describe compatibility. ControlZ EnvisaLink DSC is an independent plugin and is not endorsed by EyezOn or DSC.