ControlZ EnvisaLink Ademco plugin icon
ControlZ EnvisaLink Ademco HomeSeer HS4 plugin

Your Honeywell Vista alarm, inside HomeSeer

ControlZ EnvisaLink Ademco connects a Honeywell / Ademco Vista alarm panel to a HomeSeer HS4 hub through an EyezOn EnvisaLink running Honeywell firmware. Zones become HomeSeer sensors, partitions can be armed Away, Stay or Night and disarmed with your user code, and a Keypad page mirrors the panel's two-line ALPHA display. It talks to the EnvisaLink on your home network only.

For Vista panels only. DSC PowerSeries, EyezOn UNO and DSC Neo each have their own plugin — see Which EnvisaLink plugin?

Version 1.0.0.20 · Ready to submit to the HomeSeer Plugin Store · HomeSeer HS4 4.2 or later on Windows or Linux

Store status

ControlZ EnvisaLink Ademco is ready to submit to the HomeSeer Plugin Store. The store build is staged, and it's being tested with Vista owners before it goes to HomeSeer. It isn't available to download from this site.

  • Ready to submit: store build 1.0.0.20 is staged; the HomeSeer listing hasn't been created yet.
  • Price: US$9.95 after HomeSeer's 30-day free trial, licensed through the HomeSeer Plugin Store.
  • Beta testers wanted: no test on a live Vista panel has been recorded yet, so every report helps. Please include your Vista model, EnvisaLink version and firmware.
  • Built from the Vista TPI: the login, keypad, zone and partition messages and the arming key sequences are covered by the plugin's own self-test.

Choose the right one

Which EnvisaLink plugin?

There are four ControlZ EnvisaLink plugins. Each speaks a different EnvisaLink TPI dialect, so pick the one that matches your panel and the firmware or mode your EnvisaLink runs.

EnvisaLink DSC

DSC PowerSeries with an EnvisaLink 3 or 4 on DSC firmware. Zones with bypass, Away / Stay, panel troubles, PGMs, a graphical keypad and an optional proxy. Submitted to the HomeSeer Plugin Store. EnvisaLink DSC

EnvisaLink Ademco

Honeywell / Ademco Vista with an EnvisaLink 3 or 4 on Honeywell firmware. Zones, Away / Stay / Night, the two-line ALPHA keypad display and function keys A–D. Ready to submit. You are on this page.

EnvisaLink UNO

EyezOn UNO standalone: UNO Hybrid, SOLO, or a DUO / EVL4 MAX in standalone mode. Up to 128 zones, Away / Stay, bypass and panics. Ready to submit. EnvisaLink UNO

EnvisaLink Neo

DSC Neo through an EVL4 MAX or DUO activated in Universal mode. Arm, disarm and coarse armed / ready / alarm status only, with no zone devices. In development. EnvisaLink Neo

Run only one of them at a time: the EnvisaLink accepts a single TPI client on port 4025. If your EnvisaLink is set up for a DSC panel, this plugin is the wrong one — the Vista TPI and the DSC TPI can't be mixed.

How it works

HomeSeer becomes another Vista keypad

Vista panels are armed and disarmed through keypresses, so the plugin uses the same code-and-digit sequences you type on a real keypad.

  1. Connect to the EnvisaLink

    The plugin opens one TCP connection from your HomeSeer hub to the EnvisaLink's Vista TPI on port 4025, logs in with the TPI password and selects your default partition.

  2. Follow the keypad

    Keypad updates carry the status lights and the two-line ALPHA text; zone and partition messages update HomeSeer as they arrive. A poll every 30 seconds (minimum 15) holds the session, and it reconnects three seconds after a drop.

  3. Use native HomeSeer devices

    Zones, partitions and a Vista Keypad device appear as HomeSeer devices for Events, dashboards and apps.

  4. Arm and disarm like a keypad

    Arming and disarming send your stored user code plus a digit, one key at a time. Your panel, sirens and any monitoring contract keep working as before.

Features

What you get in HomeSeer

Zones, partitions, the ALPHA display and Vista keypad functions as HomeSeer devices and plugin pages.

🚪

Zone sensors

Each zone is a HomeSeer sensor showing Open or Closed. Set its type — door, window, motion, smoke, CO, water or glass break — and its partition (1–8).

🔢

Up to 128 zones

Read from the Vista zone bitfield: up to 64 zones on an EnvisaLink 3 and 128 on an EnvisaLink 4. The Max zones setting starts at 64.

🔐

Away, Stay and Night

Arm each partition Away (code + 2), Stay (code + 3) or Night (code + 7, Instant) from HomeSeer, the Partitions page or an Event. Confirm Night suits your panel's programming.

🔓

Disarm

Disarm sends code + 1. The Partitions page asks for confirmation first.

📊

Partition status

Ready, Not Ready, Armed Away, Stay, Night or Maximum, Exit delay, Alarm and Alarm memory, from the keypad lights and partition messages.

📟

Live ALPHA display

The panel's own two-line keypad text appears on the Status and Keypad pages, and as the partition's status text in HomeSeer.

⌨️

Graphical keypad

Keys 0–9, * and #, buffered or sent one at a time, alongside the live display and status lights for the selected partition.

✳️

Code shortcuts

Show faults, Chime, Instant, Maximum, Quick bypass and Bypass zone use the code stored on the hub, so you don't type it on the page. Quick bypass needs panel field *23 enabled.

🅰️

Function keys A–D

Sent three times to match the two-second hold, after a confirmation. What they do is set in panel field *57 — often panic or emergency — so test with monitoring off-line.

🎛️

Vista Keypad device

Door Chime and Function A–D as HomeSeer features for Events, acting on your default partition. These act immediately, without a confirmation.

🧩

Tidy HomeSeer categories

Zones are filed under Sensors, Security and ControlZ. Partitions go under Security and ControlZ only, so arm controls don't crowd your sensor lists.

🗂️

Devices view

The Status page includes the shared ControlZ Cards / Table view of every device the plugin owns, with links into HomeSeer.

🩹

Self-healing devices

Sync and Repair create or rebuild every zone, partition and keypad device from the plugin's saved settings, even while the EnvisaLink is offline.

📱

ControlZ app

With the free ControlZ Export plugin, zones and partitions can appear in the ControlZ app for iPhone, iPad and Mac through your own hub.

Compatibility

Supported panels and EnvisaLink models

ControlZ EnvisaLink Ademco speaks the Vista TPI. Other panel families need a different ControlZ plugin.

Supported Vista TPI

  • Panels — Honeywell / Ademco Vista.
  • Modules — EyezOn EnvisaLink 3 and EnvisaLink 4 running Honeywell firmware. Choose the EVL version in Settings; EnvisaLink 3 passwords are limited to 6 characters.
  • Size — partitions 1–8 and zones 1–128.
  • Panel set-up — the EnvisaLink needs a keypad address on each partition (see EyezOn's Honeywell guide) before keypad updates arrive.

Not supported Use a sibling

  • DSC PowerSeries — use EnvisaLink DSC.
  • EyezOn UNO standalone — use EnvisaLink UNO.
  • DSC Neo in Universal mode — use EnvisaLink Neo.
  • Not included — Honeywell Total Connect or any cloud path, installer programming, and a TPI proxy for Home Assistant.

HomeSeer hub HS4 4.2+

  • Windows or Linux — one package covers both.
  • Same network — the hub must reach the EnvisaLink on your LAN.
  • Plugin pages — Status, Zones, Partitions, Keypad, Settings and Help.
  • Footprint — files stay inside the HomeSeer folder.

Vista limits: zone restores can lag by about 60 seconds, and the panel sends no zone updates while armed. Vista's TPI has no panic command of its own; function keys A–D do whatever panel field *57 says.

Requirements

What you need

Check these before you connect.

  1. A HomeSeer HS4 hub

    HS4 4.2.0.0 or later on Windows or Linux, on the same network as the EnvisaLink.

  2. An EnvisaLink and a Vista panel

    An EyezOn EnvisaLink set up for Honeywell, wired to a Honeywell / Ademco Vista panel, with a keypad address assigned on each partition per EyezOn's Honeywell guide.

  3. Your user code

    Vista arms and disarms with the user code, so HomeSeer control needs it stored in Settings. Without it, arm and disarm requests are refused.

  4. No other TPI client

    Disable any DSC EnvisaLink plugin, and anything else connected to port 4025. This plugin has no proxy to share the session.

From the plugin's Help page: enable LRR / communicator support only if required, and IP shadowing only if another IP / GSM module is already fitted. Wrong panel programming has caused false alarms, so test carefully.

Security & licensing

Local, careful, and not a monitoring service

What the plugin stores, what it sends, and what it costs.

🏠

Not a monitored alarm service

The plugin adds HomeSeer as another keypad. Your panel, its sirens and any monitoring contract work as before, and nothing here replaces professional monitoring.

🌐

Local only

One outbound TCP connection from the hub to your EnvisaLink, and no listening port. No EyezOn cloud, no ControlZ server and no telemetry.

🔑

Codes stay on your hub

The TPI password and user code are saved in the plugin's registry file inside the HomeSeer folder, sent only to your EnvisaLink, and never written to any log. The file is plain JSON, so protect access to the hub.

📡

The TPI is unencrypted

Because Vista arms with the user code, the code travels as keypresses over the unencrypted TPI. Keep the EnvisaLink on a trusted network segment.

⚠️

HomeSeer controls act immediately

The Partitions page confirms Disarm and the Keypad page confirms function keys. HomeSeer device controls and Events don't ask. HomeSeer's own login is the only permission check.

🧾

Logs and screenshots

Logs include the EnvisaLink's address — never the password or user code. The ALPHA display can show zone descriptions programmed in your panel, so treat screenshots as private.

💳

Licence and price

US$9.95 after HomeSeer's 30-day free trial, bought and licensed through the HomeSeer Plugin Store. Beta keys are only used in ControlZ test builds for beta testers.

Store artwork

How it looks in the Plugin Store

Screenshots of the plugin's pages will be added once captures with masked addresses are ready.

This is the listing image prepared for the HomeSeer Plugin Store. The keypad artwork is a generic illustration by ControlZ, not an EyezOn, Honeywell or Ademco product.

ControlZ EnvisaLink Ademco store artwork: a cream alarm keypad with a green two-line display above a Plugin for HS4 banner

Plugin Store listing image

The cream keypad with a green two-line display marks the Vista plugin. The DSC, UNO and Neo plugins each have their own artwork.

HomeSeer Plugin Store · listing artwork

Setup

From install to live zones

The plugin's Help page and User Manual cover every page and setting.

  1. Install and enable

    Install from the HomeSeer Plugin Store once it's listed (beta testers receive a test package), then enable it in Plugins → Manage.

  2. Free the TPI port

    Disable any DSC EnvisaLink plugin and anything else connected to port 4025.

  3. Connect

    In Plugins → ControlZ EnvisaLink Ademco → Settings, enter the EnvisaLink host, TPI password, EVL version, user code and default partition, then save.

  4. Set up zones

    Open Zones and choose Seed. Name each zone, set its type and partition, then choose Sync HS devices.

  5. Check the keypad

    Open Status or Keypad to see the live ALPHA display. If no keypad updates arrive, check the EnvisaLink has a keypad address on each partition.

Interested in ControlZ EnvisaLink Ademco?

It's ready to submit and looking for Vista owners to test it. Use the contact form and choose ControlZ to ask about the beta, to be told when it's listed, or to ask a question.

EnvisaLink and EyezOn are trademarks of EyezOn; Honeywell, Ademco and Vista are trademarks of their owners. They are used only to describe compatibility. ControlZ EnvisaLink Ademco is an independent plugin and is not endorsed by EyezOn, Honeywell or Ademco.