Only one program can open a Boltek detector. The NexStorm Connector lets NexStorm on a Windows PC read the LD-350 or LD-250 that Lightning Monitor shares from your Mac, so both use the same detector at the same time. NexStorm becomes one more viewer, like an iPhone.
It's a stand-in for Boltek's LD350_DLL.dll with the same functions, reading the detector from the network instead of the PC's USB. Boltek's own files are kept, so you can put them back at any time. Free and open source (GPL).
Version 0.2.0 preview · Free · Windows 10 and 11 · not yet code-signed
NexStorm Connector 0.2.0 is a preview, free to download from this site. It has been tested against Lightning Monitor's own sharing and Lightning Monitor Bridge's. It isn't code-signed yet, so Windows SmartScreen may warn when you run the installer.
One installer:nexstorm-connector-setup.exe finds NexStorm, asks for the Mac's name and token, tests the connection, then installs the connector and keeps Boltek's files.
Strikes, status and waveforms: NexStorm gets everything the detector sends, with waveforms unpacked into the format Boltek's driver uses.
Settings stay with the Mac: NexStorm's squelch and alarm changes aren't sent to the shared detector unless you allow them.
LD-250 too: keep NexStorm's receiver model on LD-350 and the connector converts the LD-250's lines for it.
Reconnects by itself: if the network drops, the connector reconnects every 3 seconds and NexStorm carries on.
Easy to undo: choose 3 in the installer to restore Boltek's driver, so NexStorm opens the PC's USB again.
How it works
NexStorm reads the shared detector
NexStorm opens the detector through Boltek's LD350_DLL.dll. The connector has the same functions, but connects to the detector Lightning Monitor shares on your network.
The Mac shares the detector
The LD-350 stays on the Mac's USB. Lightning Monitor shares it on port 10001 (Settings › Detector › Sharing), protected by a token.
The connector stands in for Boltek's DLL
Setup puts the connector in NexStorm's folder as LD350_DLL.dll and keeps Boltek's copies beside it as LD350_DLL.dll.boltek.
NexStorm opens the "receiver" as usual
The connector reads its settings, connects to the Mac and hands NexStorm the detector's strikes, status lines and waveforms, as Boltek's driver would.
One more viewer
On the Mac, Settings › Detector › Sharing › Connected goes up by one. Lightning Monitor keeps working as before, with up to 16 viewers in all.
Features
What the connector does
A small 32-bit DLL, like NexStorm itself, plus a setup program that carries it.
🧩
Same functions as Boltek's DLL
It exports the functions NexStorm calls in Boltek's LD-350 Programmers Toolkit, with the same names, so NexStorm loads it without any change to NexStorm.
🖥️
Detector on the Mac or the PC
Read the detector shared by Lightning Monitor on a Mac, or a detector plugged into this PC and shared by Lightning Monitor Bridge. Any detector shared with Lightning Monitor's protocol works, including ld350-proxy.
〰️
Waveforms
Each capture is unpacked into Boltek's capture format for NexStorm. If NexStorm turns waveforms off, they only stop reaching NexStorm: they stay on for Lightning Monitor.
🎚️
Detector settings protected
NexStorm's squelch, alarm, SAVE and force-trigger commands would change the detector for every viewer, so they're held back unless you allow them. Queries such as SQ and VER always go through.
📏
Squelch safeguard
When settings are allowed, a squelch of 15 or less — only possible on the LD-250's 0–15 scale — is converted to the LD-350's 0–100 trigger level with Boltek's table before it's sent.
🔌
LD-250 through the connector
A shared LD-250 is presented to NexStorm's LD-350 mode: its status and squelch replies are converted, and GPS and EFM-100 lines are left out.
🔁
Reconnects by itself
If the connection drops, the connector tries again every 3 seconds. Lightning Monitor keeps the detector alive, so NexStorm's keep-alive only reports whether the Mac is connected.
🧪
Tests before it changes anything
The setup program tries the connection with the connector itself (up to 10 seconds) and tells you whether it works — or why not, such as a wrong token — before touching NexStorm's folder.
🔎
Finds NexStorm
It looks for a running copy, NexStorm's uninstall record and C:\Astrogenic\NexStorm, NexStorm's default folder. It closes NexStorm (asking first) and offers to start it again.
🗂️
Keeps Boltek's files
Boltek's LD350_DLL.dll beside NexStorm.exe and in its x86 and x64 folders is renamed to LD350_DLL.dll.boltek, ready to be put back.
📜
A log that explains
nexstorm-connector.log records the connection and every command NexStorm sends or is stopped from sending, with its value. The token is never logged.
⌨️
Scriptable
/install, /restore and /status from a Command Prompt, for setting up several PCs or running it from a script.
🔒
Private
The connector connects only to the detector you choose. Nothing is sent to the developer or the internet, and its log and settings stay on the PC.
Where the detector is
Two ways round
The same connector works whichever computer the detector is plugged into.
🖥️ Detector on the Mac Mac shares
Who opens the USB: Lightning Monitor on the Mac.
NexStorm reads: the Mac, by name (for example My-Mac.local) or IP address, port 10001 and the token.
Lightning Monitor reads: its own USB, as usual.
Turn on Share this detector on the network on the Mac and keep it awake.
NexStorm reads: this PC — enter 127.0.0.1 in setup.
Lightning Monitor reads: the bridge, under On this network.
The bridge can use WinUSB, because NexStorm no longer opens the USB itself. With Boltek's driver, put Boltek's own LD350_DLL.dll next to the bridge, not the connector.
Free
Download
Most people want the installer. The DLL-only zip is for setting it up by hand.
NexStorm Connector Preview
Windows 10 and 11 · NexStorm · version 0.2.0 preview, not yet code-signed
Installer:nexstorm-connector-setup.exe carries the connector, finds NexStorm, asks for the Mac's name and token, tests the connection, then installs the connector and keeps Boltek's files. DLL only:nexstorm-connector-dll.zip holds the connector and a README.txt for setting it up by hand.
SmartScreen: this preview isn't code-signed yet, so Windows SmartScreen may warn when you run the installer. Choose More info, then Run anyway.
Set up
With the setup tool
You need the Mac's name and its sharing token. With the detector on this PC instead, see Two ways round.
Share the detector on the Mac
In Lightning Monitor, open Settings… (⌘,) › Detector › Sharing and turn on Share this detector on the network. Leave the port at 10001, click Generate for a token (it's copied to the clipboard) and note Other devices connect to. Allow incoming connections if macOS asks.
Check the network from the PC
In PowerShell: Test-NetConnection My-Mac.local -Port 10001, using the Mac's name. If the name can't be resolved, use the Mac's IP address instead.
Run the installer and choose 1
Run nexstorm-connector-setup.exe and allow it to make changes. Choose 1, enter the Mac's name, port 10001 and the token (typed invisibly), and answer N to letting NexStorm change the detector's settings. It tests the connection, closes NexStorm, installs the connector and starts NexStorm again.
Check it's working
NexStorm finds the receiver as usual. The connector's log starts with Lightning Monitor NexStorm Connector 0.2.0 and Connected to …, and the Mac's Connected count goes up by one.
Setup tool
The installer's choices
It needs administrator rights. At the start it shows NexStorm's folder, whether the connector is installed and the saved detector.
1️⃣
Install or update
Install or update the connector, and choose the detector: the computer sharing it, the port and the token. Press Enter to keep the saved values.
2️⃣
Test the connection
Try the saved detector again without changing anything, and see The connection works. or the reason it didn't.
3️⃣
Restore Boltek's driver
Put Boltek's LD350_DLL.dll files back and remove the connector, so NexStorm uses this PC's USB again.
⌨️
From a Command Prompt
/install /host=My-Mac.local /token=TOKEN with optional /port=, /allow-settings, /folder="C:\Astrogenic\NexStorm" and /no-start; or /restore and /status. /install without /token keeps the saved token.
Manual setup
With the DLL only
For setting it up by hand from nexstorm-connector-dll.zip. NexStorm locks LD350_DLL.dll while it's running.
Quit NexStorm
Close NexStorm completely before changing its folder.
Swap the DLL
In NexStorm's folder (usually C:\Astrogenic\NexStorm), rename LD350_DLL.dll to LD350_DLL.dll.boltek and copy the connector's LD350_DLL.dll there. Do the same in its x86 and x64 folders if they have an LD350_DLL.dll.
Create the settings file
Create %APPDATA%\Lightning Monitor Bridge\nexstorm-connector.ini with host, port = 10001, token (empty if none) and allow_settings = 0. Use the Windows account that runs NexStorm.
Start NexStorm
Keep the receiver model set to LD-350, also for an LD-250. If NexStorm can't find the receiver, the connector's log says why.
Settings
The settings file
%APPDATA%\Lightning Monitor Bridge\nexstorm-connector.ini — the same file Lightning Monitor Bridge writes, so either can change it. Settings are read when NexStorm opens the detector: restart NexStorm after changing them.
🖥️
host
The computer sharing the detector: the Mac's name from Other devices connect to, its IP address, or 127.0.0.1 for a detector on this PC shared by the bridge.
🔢
port
The sharing port, 10001 unless you changed it in Lightning Monitor.
🔑
token
The token from Lightning Monitor's sharing settings. Leave it empty if the Mac has no token.
🎚️
allow_settings
0 (recommended) holds back NexStorm's setting changes. 1 lets NexStorm change the detector's settings for every viewer.
📏
squelch_scale
How NexStorm's squelch is turned into the LD-350's SQ when settings are allowed: auto (convert values of 15 or less), ld250 (always convert) or ld350 (never).
📜
The log
nexstorm-connector.log sits beside the settings file. It's moved to .log.old once it passes 1 MB, and never contains the token.
Squelch and filters
Which settings apply where
The detector is shared, so anything that changes the detector changes it for Lightning Monitor and every other viewer. NexStorm's own filters only change what NexStorm shows.
🎚️
Receiver squelch
The detector's trigger level. Set it on the Mac, on Lightning Monitor's Detector screen. NexStorm keeps showing its own number, which isn't the detector's.
🚨
Alarms
NexStorm sends its saved alarm values every time it starts. They control the detector's alarm lights and beeper, so set them on the Mac.
📐
A different squelch scale
NexStorm shows the LD-250's 0–15 squelch but converts it itself before sending it to an LD-350, whose SQ is a 0–100 trigger level (lower is more sensitive). NexStorm's squelch 10 arrives as SQ 76, much less sensitive than a typical 40.
📊
Boltek's table
Boltek's reference points from the LD-250 scale to the LD-350's SQ: 0 → 40, 1 → 43, 2 → 47, 4 → 53, 8 → 58, 15 → 78. The connector's log shows the value NexStorm actually sends.
🧹
NexStorm's own filters
Noise sensitivity, Discard artificial noise, Reflection inverter and Antenna alignment are NexStorm's own processing. They don't affect the detector or Lightning Monitor.
✅
Recommended
Keep NexStorm's setting changes off, set the squelch and alarms on the Mac, and leave Noise sensitivity at Default, Discard artificial noise off and the antenna alignment at North. Counts can still differ a little, because NexStorm applies its own noise filter.
LD-250
An LD-250 instead of an LD-350
NexStorm can also read a shared LD-250, from Lightning Monitor on a Mac with a USB-to-serial adapter, or from Lightning Monitor Bridge on a Raspberry Pi or PC.
🔌 Through the connector No driver
Set it up exactly as for an LD-350 and keep NexStorm's Receiver model on LD-350.
The connector converts the LD-250's status and squelch replies for NexStorm and leaves out GPS and EFM-100 lines. The log says The shared detector is an LD-250.
With settings allowed, NexStorm's squelch is converted to the LD-250's 0–15 (for example SQ 76 becomes SQ 14).
An LD-250 has no waveforms, so strikes stay unclassified.
🔀 Through a virtual COM port Coming to the bridge
For NexStorm's own LD-250 mode, with its GPS position and heading and LD-250 noise beeps.
Lightning Monitor Bridge relays the shared detector to one end of a com0com virtual port pair, and NexStorm reads the other end. This relay is in the bridge's next release.
Not yet tried with com0com on Windows. Windows 11 with Secure Boot may refuse an older signed com0com driver; if so, use the connector.
Neither way has been tried with a real LD-250 yet; both are tested with a simulated LD-250.
Undo
Restore Boltek's driver
Puts NexStorm back on this PC's own USB. Quit NexStorm first.
With the installer
Run nexstorm-connector-setup.exe and choose 3 Restore Boltek's driver, or run it with /restore.
By hand
Delete the connector's LD350_DLL.dll files in NexStorm's folder and its x86 and x64 folders, and rename the .boltek files back to LD350_DLL.dll.
Check
/status shows the connector as not installed. The settings file in %APPDATA%\Lightning Monitor Bridge\ can stay or be deleted.
Troubleshooting
What the log says
If NexStorm says it can't open the receiver, look at %APPDATA%\Lightning Monitor Bridge\nexstorm-connector.log. In PowerShell: Get-Content "$env:APPDATA\Lightning Monitor Bridge\nexstorm-connector.log" -Wait -Tail 30.
📭
No log file at all
NexStorm loaded a different LD350_DLL.dll. Run setup again, or check which DLL NexStorm loaded with Process Explorer (View › Lower Pane View › DLLs).
❓
No detector set
The settings file is missing or has no host for this Windows user. Run setup again and choose 1.
🔍
can't find … on the network
The Mac's name doesn't resolve on the PC. Use the Mac's IP address as the host.
😴
did not answer
The Mac is asleep, on another network, or its firewall is blocking Lightning Monitor. Check with Test-NetConnection.
⛔
refused the connection
Sharing is off on the Mac, or the port is wrong.
🔑
unauthorised (check the token)
The token is wrong, or the Mac has a token and the settings file's token is empty. Copy it again from the Mac.
🎚️
Not sent, NexStorm may not change …
NexStorm tried to change a detector setting and it was held back, as intended. Set it on the Mac, or allow settings and restart NexStorm.
🐢
waveforms were dropped
NexStorm read waveforms more slowly than they arrived (more than 64 waiting), so the oldest were left out.
🔒
Setup can't change the DLL
NexStorm is probably still running, perhaps asking a question. Close it and run setup again.
Requirements
What you need
The connector is an independent, free companion for Boltek owners who use both NexStorm and Lightning Monitor.
A Windows PC with NexStorm
Windows 10 or 11, and administrator rights to change NexStorm's folder.
The PC must reach the sharing computer on port 10001, and the Mac must stay awake.
Questions or problems?
This is a preview, so reports help. Use the contact form and choose Lightning Monitor, or report an issue on GitHub. Include nexstorm-connector.log — it never contains the token.
The NexStorm Connector is free software under the GPL-3.0-or-later licence, part of Lightning Monitor Bridge. Boltek, LD-350, LD-250 and NexStorm are trademarks of their owners; this project is not affiliated with Boltek.