LD-350 over USB
Reads the LD-350 directly with libusb (WinUSB on Windows), with full data including waveforms, so Lightning Monitor can classify strikes.
🪟
Boltek's driver on Windows
Prefer to keep Boltek's driver? Put LD350_DLL.dll from Boltek's LD-350 Programmers Toolkit next to the bridge. NexStorm can then use the detector again whenever the bridge is closed. The Windows build is 32-bit so Boltek's DLL can load.
🔀
Automatic driver choice
With ld350_driver set to auto (the default), the bridge uses WinUSB when it's installed and Boltek's driver otherwise. Set libusb or boltek to choose one.
🔌
LD-250 and EFM-100
Share an LD-250 or EFM-100 through a USB-to-serial adapter: set detector to ld250 and serial_port to the adapter's port, such as COM3 or /dev/ttyUSB0.
📡
Bonjour discovery
Announced on the local network as _lightningmon._tcp, so Lightning Monitor lists it under On this network with the computer's name (or the name you choose). Turn it off with advertise: false.
🔑
Token authentication
Run lightning-bridge token --new and enter the token in Lightning Monitor. Clients must then send it within 5 seconds of connecting. Without a token, anyone on the network can connect.
👥
Up to 16 devices
Macs, iPhones and iPads watch the same detector at once. A device more than 1 MB behind is disconnected so it can't hold the others up.
💓
Keeps the detector alive
The bridge sends the detector's keep-alive and status requests itself, and drops the ones clients send, so the detector is looked after once, not once per device.
🖱️
Tray and menu-bar app
Status, address, token state and client count at a glance, with Sharing on or off, Open at Login, Settings…, Reload Settings, Show Log and Quit.
⚙️
Runs as a service
lightning-bridge install-service starts it automatically with launchd, systemd or a Windows scheduled task. Add --tray for the tray app, or --system to start at boot.
🍓
Raspberry Pi installer
sudo ./install.sh copies the bridge to /usr/local/bin, adds a udev rule so the LD-350 opens without root, and starts a systemd service that runs at boot as your user.
🌀
NexStorm side by side
With the NexStorm Connector installed, NexStorm on the same PC reads the detector through the bridge instead of opening the USB itself, so NexStorm and Lightning Monitor use it at the same time.
⌨️
Command line
devices lists the detectors and serial ports the computer can see; config, token and run do the rest. Options override the settings file for one run, and the old ld_proxy.py options still work.
🔒
Private
It doesn't collect or send anything to the developer or the internet. It talks only to the detector and to the Lightning Monitor apps on your network, and its logs stay on your computer.